HA-CB05HD

Accessories
HiZone Pro CCTV Power Box 12V 20A with 18 Outputs
Model HA-DC820A18W
- Full AC input range: 100~240V
- Withstand 300VAC surge input for 5 seconds
- Protection: short circuit
- Overload
- Over voltage
- Over temperature
- Forced air cooling by built in DC fan when the current exceeds 12A. Built-in cooling fan controlled by thermal-switch
Call to orderThis product isn’t in the online shop yet. Call or WhatsApp and we’ll price it for you.
Questions? 01902 427 427Ask on WhatsApp
- Hikvision OEM: works with Hikvision recorders and cameras
- Collection in Wolverhampton or UK delivery, confirmed when we check your order
- Want it fitted? Find a recommended installer
Complete your system
Products this is most often used with.
Overview
The details that finish a professional install.
A fused CCTV power box that runs a whole analogue system from one mains supply, with protection against short circuit, overload, over voltage and over temperature.
Key features
- Full AC input range: 100~240V
- Withstand 300VAC surge input for 5 seconds
- Protection: short circuit
- Overload
- Over voltage
- Over temperature
- Forced air cooling by built in DC fan when the current exceeds 12A. Built-in cooling fan controlled by thermal-switch
Why use a power box?
A power box runs every camera from one fused, protected supply, so a fault on one camera doesn’t take down the others. It keeps wiring tidy and makes maintenance easier.
Use it with
HS-DCMS · Male DC Power Jack Screw Adapter, Pack of 100HA-DCFS · Female DC Power Jack Screw Adapter, Pack of 100HA-CB10HD · Premium HD BNC and DC CCTV Cable, 10mDVR-808XT · 8 Channel 4K AcuSense Hybrid DVR
HiZone Pro from Telexico Security
Whether you’re replacing a camera, adding to an existing system or planning a new one, Telexico Security can help you choose the right equipment and check it works with what you already have.
We supply the equipment. If you’d like it fitted, we can put you in touch with an installer from our recommended panel.
Specifications
| DC Voltage | 18V/20A |
|---|---|
| Rated Current | 20A |
| Current Range | 0∼20A |
| Rated Power | 240W |
| Voltage Adj. Range | 11.5V∼14.5V |
| Output Channels | 18-CH |
| Each Output Current | 1.1A |
| Fuse | PTC or Tube fuse, DC30V2A |
| Voltage Tolerance (Note3) | ±1.5% |
| Line Regulation (Note4) | ±0.5% |
| Load Regulation (Note5) | ±0.5% |
| Ripple & Noise (Note2) | ≤150mVp-p |
| Setup, Rise Time | 1400ms/50ms/230VAC |
| 1400ms/115VAC (at full load) | |
| Hold Up Time (Typ.) | 16ms/230VAC, 12ms/115VAC (at full load) |
| Voltage Range | 100∼240V |
| AC Current (Typ.) | 2.6A/115VAC |
| 1.3A/230VAC | |
| Frequency Range | 50∼60Hz |
| Efficiency (Typ.) | ≥85% |
| Leakage Current | < 2mA/240VAC |
| Inrush Current (Typ.) | 50A/115VAC |
| 50A/230VAC | |
| Overload (Note7) | 110∼140% rated output power |
| Protection type: Hiccup mode, recovers automatically after fault condition is removed | |
| When the current exceeds the fuse rating (ambient 25∘C), the fuse disconnects | |
| Over Voltage | 18∼21V |
| Hiccup mode, recovers automatically after fault condition is removed. | |
| Over Temperature | Hiccup mode, recovers automatically after fault condition is removed. |
| Fan ON/OFF Control (Typ.) | Hr1≥65∘C FAN ON, ≤55∘C FAN OFF |
| Working Temp. | −25∼⋯∼70∘C (Refer to "Derating Curve") |
| Working Humidity | 20%∼90% RH non-condensing |
| Storage Temp, Humidity | −40∼85∘C, 10%∼95% RH |
| Temp. Coefficient | ±0.03%/∘C (0∼50∘C) |
| Vibration | 10∼500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes |
| Safety Standards | IEC/EN/UL/CSA 60950 GB4943 |
| Withstand Voltage | I/P-O/P: 3KVAC, I/P-FG: 2KVAC, O/P-FG: 0.5KVAC |
| EMC Emission | Compliance to BSMI CNS13438, EAC TP TC 020 |
| EMC Immunity | Compliance to EAC TPTC 020 |
| Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC / 25∘C / 70% RH |
| MTBF | ≥327.9K hrs (MIL-HDBK-217F (25∘C)) |
| Dimension (L×W×H) | 290×216×68mm (L×W×H) |
| Packing | 5pcs / 13.5kg / 0.06m3 CTN |
| Product Weight | 2.5KGS |
Questions
What input does it take?
Full range 100–240V AC.